We present experimental characterization of a 20 kV, 130 mA thermionic electron gun in a W-band TWT. The gun heater voltage, focus electrode voltage, and modulating anode voltage are swept to characterize the performance of the emitted cathode current and beam transport through the RF circuit. We observe variation of the cathode current from 107 to 155 mA and peak beam transmission of 95% at the collector. Experimental results are compared to 2D MICHELLE simulations.