Comparison of Magnetic Field Analysis Methods Considering Magnetic Anisotropy
2010
The magnetic field analysis results on grain-oriented silicon steel sheet and nongrain-oriented silicon steel sheet by the isotropic method, the two-axis isotropic method, the two-axis anisotropic method, the ? anisotropic method, and the ? HB anisotropic method, which are 2-D magnetic analysis methods, are compared. In analyzing the magnetic field in the isotropic material, the isotropic method is more appropriate than the two-axis isotropic method. For the anisotropic material in which the magnetic flux density is much less than saturation magnetic flux density, the two-axis anisotropic method is more preferable than the ? anisotropic method, because the result of the two-axis anisotropic method is similar to that of the ? HB anisotropic method. However, for the analysis in high magnetic flux density near the saturation magnetic flux density, the ? anisotropic method is more suitable than the two-axis anisotropic method.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
8
References
21
Citations
NaN
KQI