A new approach to the analysis of thermoluminescence glow-curve of TLD-600 dosimeters following Am-241 alpha particles irradiation

2018 
A new approach to the analysis of thermoluminescence (TL) glow-curves of LiF:Mg, Ti (TLD-600) following alpha particles irradiation has been presented using general expressions derived from the one-trap-one recombination (OTOR)-level model. It has been found that the results of the deconvolution in the case of using these expressions are different from the case of using the other TL expressions, especially for the high-temperature region. The advantage of using the OTOR expressions is that, unlike the usual analysis, a good fit and reasonable kinetic parameter values could be obtained with a lower number of deconvoluted peaks. The kinetic parameters and the dosimetric properties of each peak have been investigated over different absorbed doses and new findings have been found. Improvement of the accuracy and the precision of the dose measurements at low-dose levels has been achieved using the glow-curve deconvolution algorithm. In addition, theoretical interpretations of some observed behaviors have been presented using the interactive multiple trap system model.