Laboratory demonstration of a cryogenic deformable mirror for wavefront correction of space-borne infrared telescopes

2017 
This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-static DM with a special surrounding structure for use under the cryogenic temperature. We conducted a laboratory demonstration of its operation in three cooling cycles between 5 K and 295 K. Using a laser interferometer, we detected the deformation corresponding to the applied voltages under the cryogenic temperature for the first time. The relationship between voltages and displacements was qualitatively expressed by the quadratic function, which is assumed based on the principle of electro-static DMs. We also found that it had a high operating repeatability of a few nm RMS and no significant hysteresis. Using the measured values of repeatability, we simulated the improvement of PSF by wavefront correction with our DM. These results show that our developed DM is effective in improving imaging performance and PSF contrast of space-borne infrared telescopes.