Comparison Between the Ultraviolet Emission From Pulsed Microhollow Cathode Discharges in Xenon and Argon

2003 
We measured the dynamic I–V characteristics and vacuum ultraviolet (VUV) emission lines of the second continuum in xenon (170 nm) and argon (130.5 nm) from pulsed microhollow cathode discharges (MHCD). For pulse lengths between 1 and 100 μs the dynamic I–V characteristics are similar in both inert gases. Only the time variation of the VUV emission line at 170 nm for xenon can be related to the dimer excited states. In argon the energy transfer between the Ar2* dimers and the oxygen impurity atoms is responsible for a qualitatively different time behavior of the resonance line at 130.5 nm. Consequently, the relative VUV efficiency reveals an inverse dependence on the electrical pulse lengths for the MHCD in xenon and argon, respectively.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    17
    References
    15
    Citations
    NaN
    KQI
    []