Enhanced mass resolution method development, validation and assay application to support preclinical studies of a new drug candidate

2006 
A very highly sensitive and highly selective liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed to evaluate and quantify a new drug candidate in different biological matrices. Following a simple plasma protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C18 column interfaced with a new generation of triple-quadrupole mass spectrometer. The recently introduced triple-quadrupole mass spectrometer, the TSQ Quantum Ultra, with enhanced mass-resolution capability, demonstrated improved sensitivity (0.05 ng/mL), coupled with suitable accuracy and precision, over a broad linear dynamic range (0.05–1000 ng/mL). A comparison of the assay performance data (dynamic range, calibration curve equation, precision and accuracy) of the enhanced resolution method against a unit resolution method under optimized conditions showed the performance improvement of the enhanced mass resolution method for bioanalytical high-throughput applications. The enhanced mass resolution method herein described was successfully applied to the evaluation of the pharmacokinetic profile of a new drug candidate in rat, rabbit and dog plasma samples. Copyright © 2006 John Wiley & Sons, Ltd.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    9
    References
    11
    Citations
    NaN
    KQI
    []