Bottom axial diagnostic package on Z

2004 
A bottom axial diagnostic package has recently been developed and fielded on the 100 ns, 20 MA pinch-driver Z. The bottom package was developed to measure the power radiated to the bottom of Z and compare it to the power radiated to the top of Z on dynamic hohlraum pinch loads. When an up/down power asymmetry was measured, the bottom package was expanded in an effort to determine the source of the asymmetry. The bottom package contains one port directly on axis, six ports at 3.4° to the axis, and four ports at 9° to the axis. Typical diagnostics fielded on the bottom package are a time-resolved pinhole camera, time-integrated spatially resolved convex crystal spectrometers, a time-resolved crystal spectrometer, x-ray diodes, bolometers, and photoconducting detectors. We will present some typical data from these bottom diagnostics on dynamic hohlraum shots on Z and briefly discuss their relevance to the up/down power asymmetry.