AC losses in HTSC conductor elements

2008 
AC self field losses and DC ‘‘dynamic resistivity’’ in HTSC conductor elements have been measured. The data are discussed with reference to the relevant theory. For two very different sample types, the Jc calculated on the basis of the AC self field loss is about an order of magnitude lower than the Jc based on the 1 μV/cm DC voltage drop criterion often employed for HTSC materials. This is attributed to the onset of resistive behavior at currents much lower than the reported Jc based on the 1 μV/cm criterion. The Jc determined from measurements of the dynamic resistivity of a melt‐textured YBCO fiber is within 15% of that determined by magnetic measurements.