The liquid-hydrogen absorber for MICE

2018 
This paper describes the liquid hydrogen system constructed for The Muon Ionization Cooling Experiment (MICE); MICE was built at the STFC Rutherford Appleton Laboratory to demonstrate the principle of muon beam phase-space reduction via ionization cooling. Muon beam cooling will be required at a future proton-derived neutrino factory or muon collider. Ionization cooling is achieved by passing the beam through an energy-Absorbing material, such as liquid hydrogen, and then re-Accelerating the beam using RF cavities. This paper describes the system creating the 22l of liquid hydrogen within the MICE beamline; the necessary safety engineering, the liquid hydrogen absorber and its associated cryogenic and gas systems are presented, along with its performance.