Degradation of Alloy 690 After Relatively Short Times

2016 
The purpose of this work is to understand quantitative processes which underlie the initiation of stress corrosion cracking (SCC) of cold-worked, thermally treated Alloy 690 after long-term exposures in high-temperature water. Long-term stress corrosion cracking initiation tests up to 34,484 h have been performed on cold-worked, thermally treated Alloy 690 under static load conditions using 0.5T compact tension specimens with a shallow depth of the precrack (0.1 mm to approximately 0.3 mm) and blunt notch compact tension type specimens. These specimens were exposed in the primary coolant environments of pressurized water reactors under static load conditions both at 320°C and 360°C. Three important patterns were observed. First, intergranular cracking observed from the shallow precracks after 21,838 h at 320°C and 20,653 h at 360°C, respectively, in 20% cold-worked Alloy TT690 in primary water. Second, clear evidence of cavities were identified ahead of the SCC-tip after the tests both at 360°C and 320°C....