Grandeurs Dosimétriques en Scanner Pediatrique dans Deux Centres d’Imagerie Medicale de la Ville de Douala: Assessment of dosimetric quantities by pediatric scanner in two medical imaging centers in the city of Douala, Cameroon

2021 
RESUME Introduction. Les procedures de radio-diagnostic representent plus de 97% de l'exposition aux rayonnements ionisants d'origine artificielle, dont la tomodensitometrie (TDM) est l'une des principales sources. La population pediatrique est plus radio-sensible aux rayonnements ionisants que celle des adultes. Le but de cette etude etait de determiner les doses d’irradaiation delivrees aux enfants lors des differents scanners effectues la ville de Douala et de les comparer aux Niveaux de Reference Diagnostiques (NRD) pediatriques internationaux. Materiels et methodes. Il s'agissait d'une etude transversale et descriptive realisees sur une periode de cinq mois dans 2 centres a Douala. Les parametres techniques (kV, mAs et pitck) ainsi que les valeurs theoriques de dose absorbee (CTDIw et DLP) ont ete determines pour la TDM chez des patients âges de 0 a 15 ans. Resultats. Sur un total de 78 patients inclus, majoritairement de sexe masculin, la tension etait superieure a 120 kV dans 35,90% cas, contituant un depassement important des NRD selon les recommandations de la SFIPP et de l’IRSN. De memes les IDSV et PDL contrastaient egalement avec les NRD, avec une difference pouvant aller jusqu’a 40 mGy pour les IDSV et 1127 mGy.cm pour les PDL. Conclusion. Les doses d’exposition delivrees aux enfants lors d’examens tomodensitometriques sont au-dessus des NRD recommandes pour une certaine partie des examens. Des efforts de justification et d’optimisation des procedures radiologiques demeurent, par ailleurs, encore necessaires pour reduire les doses delivrees en pediatrie.ABSTRACTIntroduction. Radiology procedures represent more than 97% of the ionizing radiation exposure of artificial origin, of which CT-scan practice is one of the main source. The pediatric population is more radio-sensitive to ionizing radiation than that of adults. The aim of this study was to determine the radiation doses delivered to children during the various CT examinations carried out in the city of Douala and to compare them with international pediatric diagnostic reference levels (DRLs). Patients and Methods. This was a cross-sectional and descriptive study carried out over a period of five months in 2 centers in Douala. The technical parameters (kV, mAs and pitck) as well as the theoretical absorbed dose values (CTDIw and DLP) were determined for CT in patients aged 0 to 15 years. Results. Out of a total of 78 patients included, mostly male, the voltage was greater than 120 kV in 35.90% of cases, constituting a significant exceedance of the NRDs according to the recommendations of the SFIPP and IRSN. Similarly, IDSVs and PDLs also contrasted with NRDs, with a difference of up to 40 mGy for IDSVs and 1127 mGy.cm for PDLs. Conclusion. The exposure doses delivered to children during CT scans are above the recommended DRLs for some part of the scans. Efforts to justify and optimize radiological procedures are also still necessary to reduce the doses delivered to pediatrics.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    3
    References
    0
    Citations
    NaN
    KQI
    []