Sagittal T1-weighted series with 3-mm sections have routinely been used for all cranial MR studies at our institution. It was apparent from examining these studies that the rate of occurrence of a normal posterior pituitary bright signal was lower than has been previously reported, particularly in older patients. This prompted both a retrospective and a prospective review and analysis of the posterior lobe bright signal in three patient categories. The overall frequency of posterior pituitary bright signal and the influence of sex and age were evaluated in one category. An age-related statistically significant decline in the frequency of posterior pituitary bright signal was found, with a decline rate of approximately 1% per year. An evaluation of the occurrence of anatomic variation in the location of posterior lobe bright signal was made in a second group of 1500 patients. Abberrant location of the posterior lobe was found to be uncommon and was seen most frequently in patients with a sellar fossula. Te...