ONE-SIDED MUON TOMOGRAPHY—A PORTABLE METHOD FOR IMAGING CRITICAL INFRASTRUCTURE WITH A SINGLE MUON DETECTOR

2016 
High-energy muons generated from cosmic-ray particle showers have been shown to exhibit properties ideal for imaging the interior of large and dense structures. This paper explores the possibility of using a single portable muon detector in conjunction with image reconstruction methods used in nuclear medicine to reconstruct a 3-D image of the interior of critical infrastructure such as the Zero-Energy Deuterium (ZED-2) research reactor at Canadian Nuclear Laboratories’ Chalk River site. The ZED-2 reactor core and muon detector arrangement are modeled in GEANT4 and Monte Carlo measurements of the resultant muon throughput and angular distribution at several angles of rotation around the reactor are generated. Statistical analysis is then performed on these measurements based on the well-defined flux and angular distribution of muons expected near the surface of the earth. The results of this analysis are shown to produce reconstructed images of the spatial distribution of nuclear fuel within the core for ...