Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws

2016 
OBJECTIVE Loosening and pullout of pedicle screws are well-known problems in pedicle screw fixation surgery. Augmentation of pedicle screws with bone cement, first described as early as 1975, increases the pedicle-screw interface and pullout force in osteoporotic vertebrae. The aim of the present study was to identify cement leakage and pulmonary embolism rates in a large prospective single-center series of pedicle screw augmentations. METHODS All patients who underwent cement-augmented pedicle screw placement between May 2006 and October 2010 at the authors' institution were included in this prospective cohort study. Perivertebral cement leakage and pulmonary cement embolism were evaluated with a CT scan of the area of operation and with a radiograph of the chest, respectively. RESULTS A total of 98 patients underwent placement of cement-augmented pedicle screws; 474 augmented screws were inserted in 237 vertebrae. No symptomatic perivertebral cement leakage or symptomatic pulmonary cement embolism was o...