Clinical Utility of Home versus Hospital Spirometry in Fibrotic ILD: Evaluation Following INJUSTIS Interim Analysis.

2021 
Abstract The COVID-19 pandemic identified an urgent need to re-evaluate the provision of spirometry for clinical monitoring. Home spirometry offers the opportunity for real-time disease evaluation without risk of nosocomial infection. To determine the utility of home spirometry in interstitial lung disease (ILD), interim data from the ongoing INJUSTIS study was evaluated. High correlation was observed between home and hospital spirometry at baseline(r=0.89) and three-months(r=0.82). Over 90% of home spirometry values were within Bland-Altman agreement limits at both time points, although frequently underestimated hospital values. Home spirometry is feasible in people with fibrotic ILD.