A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation

2020 
Background and Aims: The aim of this study was to compare the efficacy of McGRATH series 5 videolaryngoscope (VL) with Macintosh laryngoscope for nasotracheal intubation (NTI) in patients without anticipated difficult airways undergoing head and neck cancer surgeries. Material and Methods: We randomized 60 adult patients for NTI by experienced anesthetists with either Macintosh laryngoscope or McGRATH series 5 VL (VL group). The primary objective was to compare time taken for intubation (TTI). The secondary objectives included success rates, number of attempts, need for optimization maneuvers, Cormack and Lehane (CL) grade, and percentage of difficult intubations. Results: The mean TTI in the VL group was 43 (±10.6) versus 75 (±38.0) s in the Macintosh group (99% CI: 12.5; –51.6 s; P Conclusion: The McGRATH series 5 VL has faster TTI, better glottic visualization, and less need for optimization maneuvers than the Macintosh laryngoscope for NTI in patients with unanticipated difficult airways, when performed by experienced anesthetists.