SPECT/CT Correlation in the Diagnosis of Unilateral Condilar Hyperplasia

2021 
Objective: To evaluate the correlation between metabolic bone activity measured by single photon emission computed tomography (SPECT) and the anatomic condylar characteristics acquired by computed tomography (CT), in patients with unilateral condylar hyperplasia (UCH). Method and Materials/Patients: Observational, descriptive study in a group of 71 patients with clinical diagnosis of UCH and indication of SPECT/CT. Bone SPECT images obtained in a gamma-camera GE Infina and processed in a station Xeleris 3 with the program Volumetrix MI Evolution for bone. CT images acquired in a PET/CT Biograph mcT20 equipment (Siemens) processed in a station Osirix V 7.5.1 (Pixmeo, Bomex, Switzerland). Results: The sample included 24 men (33.8%) and 47 women (66.2%). Active state UCH was detected in 40 (56.3%) cases (over 55% uptake in the affected condyle) and 38 (53.5%) presented mandibular deviation to the right side. No significant differences related to sex, age, or mandibular deviation side were found. Mandibular deviation was the only morphologic feature related to active/inactive UCH (p = 0.003). The likelihood of active CH was significantly higher in patients with mandibular deviation higher than 6 mm compared with 6 mm.