Effect of Different Channels on Discharge Coefficient of Labyrinth Weirs

2021 
In this study, the effect of channel-bed slope and non-prismatic converging channel on the discharge coefficient of labyrinth weirs is numerically investigated utilizing FLOW-3D model. Numerical simulation results show that modifying the labyrinth weir channel through both methods improves the discharge coefficient. Among the selected bed slopes and converging channel wall, the slope of β=4% and angle of θ=10° yielded the highest discharge coefficient. For a ratio HT/P=0.1, (HT: flow height, P: weir height) the discharge coefficient and discharge rate for bed slope and convergence angle case were 19.22%, 23.9% and 22.28%, 25.91% higher than for a conventional labyrinth weir in prismatic channel, respectively. Simultaneous application of a bed slope and convergence angle significantly increases the discharge coefficient and discharge value case were 28.64% and 30.42% higher than compared to the conventional case. Therefore, changing the bed slope and wall angle of the weir channel increases the discharge coefficient and in this type of weir and these design alterations should be considered in weir design.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    1
    Citations
    NaN
    KQI
    []