By using the optimal control theory and the scheme of stepping search for the self-optimizing control,an optimal air-fuel ratio is determined through relation curves between thermal efficiency and air coefficient of boiler under various operating conditions at different loads,so as to achieve a complete burning of fuel and optimal thermal efficiency of boiler.