Accuracy of Palpation-Guided Catheter Placement for Muscle Pressure Measurements in Suspected Deep Posterior Chronic Exertional Compartment Syndrome of the Lower Leg A Magnetic Resonance Imaging Study

2016 
Background:A diagnosis of lower leg deep posterior chronic exertional compartment syndrome (dp-CECS) is made by a dynamic pressure measurement. The insertion of a pressure catheter is guided by anatomic landmarks (freehand) or by ultrasound. The catheter tip is ideally positioned in the tibialis posterior muscle (TP). The accuracy of in vivo catheter placement using lower leg magnetic resonance imaging (MRI) in healthy patients suspected of having dp-CECS has never been studied.Purpose:To analyze whether a freehand catheter insertion results in accurate positioning in the TP as confirmed by MRI in patients with suspected dp-CECS.Study Design:Case series; Level of evidence, 4.Methods:Catheters were inserted into central portions of the TP using a standard puncturing technique guided by lower leg anatomic landmarks. After timed muscle pressure measurements during a standard provocative treadmill running test, lower leg MRI scans were obtained and evaluated by 2 skilled radiologists. Catheter tip placement w...