Simultaneous Integrated Boost Volumetric Modulated Arc Therapy for Middle or Lower Esophageal Cancer Using Elective Nodal Irradiation: Comparison with 3D Conformal Radiotherapy

2019 
We investigated the feasibility of simultaneous integrated boost (SIB) volumetric modulated arc therapy (VMAT) using elective nodal irradiation (ENI) for middle or lower esophageal cancer and compared it with three-dimensional conformal radiotherapy (3D-CRT). The study included 15 patients. The prescribed doses included a standard dose (50.4 Gy) and a high dose (60 Gy) for the planning target volume (PTV) of the involved lesions. The objective of the whole lung volume receiving ≥ 20 Gy (V20Gy) was 20% reduction in the mean against 3D-CRTs. Our results demonstrate the feasibility of SIB-VMAT for the treatment of middle or lower esophageal cancer with ENI. Although attention should be paid to the low-dose area of the lungs, SIB-VMAT would be a promising treatment option with improved outcomes for esophageal cancer.
    • Correction