Contribution of AE analysis in order to evaluate time to failure of ceramic matrix composites

2019 
Abstract The paper presents an empirical approach to obtain the Remaining Useful Lifetime (RUL) or Time To Failure (TTF) using mechanical parameters or Acoustic Emission (AE) of Ceramic Matrix Composite (CMC) submitted to static fatigue tests at the laboratory scale. The approach is based on the investigation of the AE dynamic and identification of characteristic times with several indicators such as the sentry function, coefficient R AE , coefficient of attenuation B. A linear correlation is established between these characteristics times and the time to failure allowing the possibility of evaluating the Time To Failure in real time. The results are compared to those obtained with mechanical parameters such as the strain and the damage parameter.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    50
    References
    17
    Citations
    NaN