Influence of Screw-Hole Defect Size on the Biomechanical Properties of Feline Femora in an Ex Vivo Model

2021 
Objective The study aims to evaluate the biomechanical properties of feline femora with craniocaudal screw-hole defects of increasing diameter, subjected to three-point bending and torsion to failure at two different loading rates. Study Design Eighty femoral pairs were harvested from adult cat cadavers. For each bending and torsional experiment, there were five groups (n = 8 pairs) of increasing craniocaudal screw-hole defects (intact, 1.5 mm, 2.0 mm, 2.4 mm, 2.7mm). Mid-diaphyseal bicortical defects were created with an appropriate pilot drill-hole and tapped accordingly. Left and right femora of each pair were randomly assigned to a destructive loading protocol at low (10 mm/min; 0.5 degrees/s) or high rates (3,000 mm/min; 90 degrees/s) respectively. Stiffness, load/torque-to-failure, energy-to-failure and fracture morphology were recorded. Results Defect size to bone diameter ratio was significantly different between defect groups within bending and torsional experiments respectively (intact [0%; 0%], 1.5 mm [17.8%; 17.1%], 2.0 mm [22.8%; 23.5%], 2.4 mm [27.8%; 27.6%], 2.7 mm [31.1%; 32.4%]) (p  Conclusion Screw-hole defects up to 2.7 mm did not significantly reduce feline bone failure properties in this ex vivo femoral study. These findings support current screw-size selection guidelines of up to 33% bone diameter as appropriate for use in feline fracture osteosynthesis.