Influence of the ambient pressure on the liquid accumulation and on the primary spray in prefilming airblast atomization

2020 
Abstract The influence of the ambient pressure on the breakup process is investigated by means of PIV and shadowgraphy in the configuration of a planar prefilming airblast atomizer. The ambient pressure is varied from 1 to 8 bar. Other investigated parameters are the gas velocity and the film loading. From single-phase PIV measurements, it is found that the gas velocity in the vicinity of the prefilmer partly matches the analytical profile from the near-wake theory. the characteristics of the liquid accumulation are extracted from the shadowgraphy images of the liquid phase directly downstream of the prefilmer. Two different characteristic lengths, as well as the ligament velocity and a breakup frequency are determined. In addition, the droplets generated directly downstream of the liquid accumulation are captured. Hence, the spray Sauter Mean Diameter (SMD) and the mean droplet velocity are given for each operating point. The novelty of this study is that a scaling law of these quantities with regard to ambient pressure is derived. A correlation is observed between the characteristic length of the accumulation and the SMD, thus reinforcing the idea that the liquid accumulation determines the primary spray characteristics. In this paper, a threshold to distinguish the zones between primary and secondary breakup is proposed based on an objective criterion. It is also shown that taking non-spherical droplets into account significantly modifies the shape of the dropsize distribution, thus stressing the need to use shadowgraphy when investigating primary breakup. Additionally, the ambient pressure and the velocity are varied accordingly to keep the aerodynamic stress ρ g U g 2 constant. This leads to almost identical liquid accumulation and spray characteristics. Hence, it is confirmed that the aerodynamic stress is a more appropriate parameter than the gas velocity or the ambient pressure to characterize prefilming airblast breakup. Finally, SMD correlations from the literature are compared to the present experiment. Most of the correlations calibrated with LDA/LDT measurement underestimate the SMD. This highlights the need to use shadrowgraphy for calibrating primary breakup models.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    50
    References
    11
    Citations
    NaN
    KQI
    []