Effect of drug-coated balloon angioplasty on in-stent restenotic coronary lesions analyzed with optical coherence tomography and serial coronary artery angioscopy

2019 
Drug-coated balloon angioplasty (DCBA) has been recognized for its utility in preventing in-stent re-restenosis (ISR); however, imaging of the neointima immediately after treatment and during follow-up has only been described in a few case reports. This study aimed to determine the efficacy and mechanism of the DCBA using imaging studies both immediately after the DCBA and during the follow-up period. We enrolled 15 consecutive patients who underwent DCBA for in-stent restenosis (ISR). The in-stent neointimal volume was evaluated using optical coherence tomography (OCT), and the in-stent yellow grade was assessed using coronary angioscopy (CAS) immediately after DCBA and during the median follow-up period of 9 (8–15) months. The neointimal volume was significantly reduced from 77.1 ± 36.2 mm3 at baseline to 60.2 ± 23.9 mm3 immediately after DCBA (p = 0.0012 vs. baseline) and to 46.7 ± 21.9 mm3 during the follow-up (p = 0.0002 vs. post DCBA). The yellow grade of the residual plaques at the ISR lesion, which indicated plaque vulnerability, was significantly decreased in the follow-up CAG (from baseline: 1.79 ± 1.03, during the follow-up: 0.76 ± 0.82; p < 0.0001). These data suggest that DCBA may inhibit neointimal formation and provide angioscopic intimal stabilization for ISR lesions.