A PRELIMINARY SIMULATION OF BPM SIGNAL DIODE DETECTOR FOR HLS II TUNE MEASUREMENT SYSTEM

2013 
A high sensitivity BPM signal detection front-end electronics has been designed for HLS II tune measurement system according to the HLS II upgrade requirements. Classical tune measurement systems filter out just one or a few of these betatron sidebands frequency, as a consequence, most of the betatron energy is dropped and only a very small energy remains for further processing. A new method, referred to as Direct Diode Detection (3D) by LHC [1] , improves this situation. In this paper, the HLS II BPM signals have been calculated out in time domain and frequency domain. Basing on the characteristics of HLS II BPM signals, a preliminary simulation is performed to test and verify the feasibility of diode detector for HLS II tune measurement system. The simulation results clearly show that the technique of diode-based circuit can be applied to HLS II tune measurement.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    6
    References
    0
    Citations
    NaN
    KQI
    []