Airway control in case of a mass toxicological event: superiority of second-generation supraglottic airway devices.

2014 
Abstract Introduction Early respiratory support and airway (AW) control with endotracheal intubation (ETI) are crucial in mass toxicology events and must be performed while wearing chemical personal protective equipment (C-PPE). Aim The aim of this study is to evaluate the efficiency of AW control by using second-generation supraglottic AW devices (SADs) as compared with ETI and first-generation SAD while wearing C-PPE. Methods This is a randomized crossover trial involving 117 medical practitioners. Four AW management devices were examined: endotracheal tube, the first-generation SAD, laryngeal mask AW unique and 2 second-generation SAD, the laryngeal tube suction disposable, and supreme laryngeal mask AW (SLMA). Primary end point measured were success or failure, number of attempts, and time needed to achieve successful device insertion. Secondary end point was a subjective appraisal of the AW devices by study population. Results More attempts were required to achieve AW control with endotracheal tube, with and without C-PPE ( P P Conclusions When compared with ETI, the use of SADs significantly shortened the time for AW control while wearing C-PPE. Second-generation SAD were superior to laryngeal mask AW unique. These finding suggest that SADs may be used in a mass toxicology event as a bridge, until definite AW control is achieved.