Tutorial on single- and two-component two-phase flow and heat transfer: Commonality and difference

2002 
It is assessed to what extent the results of two-phase two-component flow and heat transfer research can be usefully applied to support research on the flow and heat transfer in two-phase single-component systems. The latter single-component two-phase systems, envisaged for spacecraft thermal control applications, are Mechanically Pumped and Vapor Pressure Driven Loops, Capillary Pumped Loops, and Loop Heat Pipes. In these single-component systems the working fluid is a mixture of a liquid (for example ammonia, carbon dioxide, ethanol, or other refrigerants, etc.) and its saturated vapor. The two-component systems considered consist of liquid-gas mixtures, e.g. water-air. Various aspects are discussed qualitatively and quantitatively to determine commonality and difference between two physically looking similar and close, but essentially different systems. It is focused on the different pressure gradient constituents and total pressure gradients, on flow regime mapping (including evaporating and condensin...