A novel size-selective airborne particle size fractionating instrument for health risk evaluation.

2009 
Health risks associated with the inhalation of airborne particles are known to be influenced by particle size. Studies have shown that certain nanoparticles, with diameters <100 nm, have increased toxicity relative to larger particles of the same substance. A reliable, size-resolving sampler able to collect a wide range of particle sizes, including particles with sizes in the nanometre range, would be beneficial in investigating health risks associated with the inhalation of airborne particles. A review of current aerosol samplers used for size-resolved collection of airborne particles highlighted a number of limitations. These could be overcome by combining an inertial deposition impactor with a diffusion collector in a single device. Verified theories of diffusion and inertial deposition suggested an optimal design and operational regime. The instrument was designed for analysing mass distribution functions. Calibration was carried out using a number of recognized techniques. The sampler was tested in the field by collecting size-resolved samples of lead containing aerosols present at workplaces in factories producing crystal glass. The mass deposited on each screen proved sufficient to be detected and measured by an appropriate analytical technique. Mass concentration distribution functions of lead were produced. The nanofraction of lead in air varied from 10 to 70% by weight of total lead.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    41
    References
    36
    Citations
    NaN