A stability indicating High-Performance Liquid Chromatography (HPLC) method was validated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidative conditions. The separation was carried out on a Symmetry C 18 column and a mixture of 50 mM KH 2 PO 4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method was linear over the range of 1-20 µg/mL of cetirizine dihydrochloride (r 2 > 0.999) and the withinday and between-day precision values were less than 1.5%. The results showed that cetirizine dihydrochloride was unstable in 2 M HCl and 0.5% H 2 O 2. The kinetics of the acidic degradation showed a pseudo-first-order reaction in the temperature range of 70-90 °C. In addition, the kinetics of hydrogen peroxide mediated degradation was pseudo-first-order in the temperature range of 50-80°C.