Different Stabilization Techniques for Type 62B3 Acetabular Fractures in Combination With Primary Total Hip Arthroplasty in Elderly Patients: A Biomechanical Comparison

2016 
Introduction:The total hip arthroplasty (THA) as part of acute fracture management is used for acetabular fractures in elderly patients. Our objective was to assess the stability of osteosynthesis performed using 2 different techniques in combination with THA in an experimental model.Materials and Methods:We conducted 20 experiments using the left-side hemipelves composite bone models. There were 2 testing groups: 1- and 2-stage osteosynthesis. The acetabular fractures of the anterior column and posterior hemitransverse were simulated. The same THA technique was used in both groups. The stability of osteosynthesis was explored and compared between the groups by measuring the fracture displacement of anterior and posterior columns under the standardized test load (1187 N) protocol. Load distance diagrams were generated.Results:The 0.680-mm gap (0.518; 1.548) of the posterior column in the 1-stage group (n = 10) was higher than the 0.370-mm gap (0.255; 0.428) in the 2-stage group (n = 10; P = .002). There w...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    17
    References
    0
    Citations
    NaN
    KQI
    []