Validation of Normal P-Wave Parameters in a Large Unselected Pediatric Population of North-Western Romania: Results of the CARDIOPED Project

2021 
Aims. Reference values of the P-wave on 12 lead electrocardiograms are lacking for children and adolescents in Eastern Europe. Hence, the present study is aimed at determining the standard values of the P-wave in children and adolescents based on ECG data from the CARDIOPED project, a large-scale general population of children who participated in a screening program in Transylvania, Romania. Methods and Results. A total of 22,411 ECGs of participants aged 6 to 18 years old from a school-based ECG screening were obtained between February 2015 and December 2015 in Transylvania, Romania. Three pediatric cardiologists manually reviewed each ECG. P-wave duration, voltage, axis, and correlation with gender and age were analyzed. The mean P-wave duration was , with a maximum duration of 128 ms. P-wave showed a positive correlation with age but did not differ between sexes. There was a positive correlation between the P-wave duration and the heart rate, but not with the body max index. The mean P-wave axis was , and the mean P-wave amplitude was . Conclusion. In this study on many pediatric subjects, we have provided normal limits for the P-wave in Romanian children aged 6-18 years. Our findings are useful for creating interpretation guidelines for pediatric ECG.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    28
    References
    0
    Citations
    NaN
    KQI
    []