Quality of chest compressions during pediatric resuscitation with 15:2 and 30:2 compressions-to-ventilation ratio in a simulated scenario.

2020 
The main objetive was to compare 30:2 and 15:2 compression-to-ventilation ratio in two simulated pediatric cardiopulmonary resuscitation (CPR) models with single rescuer. The secondary aim was to analyze the errors or omissions made during resuscitation. A prospective randomized parallel controlled study comparing 15:2 and 30:2 ratio in two manikins (child and infant) was developed. The CPR was performed by volunteers who completed an basic CPR course. Each subject did 4 CPR sessions of 3 minutes each one. Depth and rate of chest compressions (CC) during resuscitation were measured using a Zoll Z series defibrillator. Visual assessment of resuscitation was performed by an external researcher. A total of 26 volunteers performed 104 CPR sessions. Between 54–62% and 44–53% of CC were performed with an optimal rate and depth, respectively, with no significant differences. No differences were found in depth or rate of CC between 15:2 and 30:2 compression-to-ventilation ratio with both manikins. In the assessment of compliance with the ERC CPR algorithm, 69.2–80.8% of the subjects made some errors or omissions during resuscitation, the most frequent was not asking for help and not giving rescue breaths. The conclusions were that a high percentage of CC were not performed with optimal depth and rate. Errors or omissions were frequently made by rescuers during resuscitation.