Evaluation of trapping parameters of annealed natural quartz

2016 
Abstract The thermoluminescence (TL) trapping parameters of annealed quartz have been investigated. The apparent TL peaks observed at temperatures of 133 °C, 211 °C, 266 °C and 405 °C, respectively, were named Peak I, Peak II, Peak III and Peak IV. The T m  −  T stop method is applied to investigate the number of peaks and their positions, and to obtain the trap distributions in the quartz. Peak shape (PS), Hoogenstraaten method (Various Heating Rates Method, VHR), and Computerized Glow Curve Deconvolution (CGCD) are used to evaluate the trapping parameters of the annealed quartz. The glow curve can be considered as a superposition of at least nine overlapping peaks. These peaks show up at 133 °C, 211 °C, 266 °C, 308 °C, 333 °C, 384 °C, 441 °C, 466 °C and 484 °C. The PS method can be only used in evaluating the parameters for Peaks I. The VHR method can be used in evaluating the trapping parameters for the first three peaks. CGCD method is complementary to obtaining parameters for the sub-peaks, and the thermal quenching correction with the Urbach’s method is necessary. The Urbach’s coefficient for the quartz is 30.03 k T m .
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    28
    References
    7
    Citations
    NaN
    KQI
    []