USE OF VIRAL FILTER TO REDUCE EXPOSURE TO EXHALED AEROSOL DOES NOT AFFECT METHACHOLINE DOSE DELIVERY DURING BRONCHOPROVOCATION TESTING

2021 
TOPIC: Respiratory Care TYPE: Original Investigations PURPOSE: Methacholine challenge testing (MCT) is a common bronchoprovocation technique used to assess airway hyperresponsiveness. Current ERS guidelines recommend that measures should be taken to minimize technician exposure to methacholine aerosol, with added infection control concerns in the context of the ongoing COVID-19 pandemic. We previously demonstrated that the addition of a viral filter to the nebulizer exhalation limb reduced expelled particle concentrations by 77-91% during MCT. Our aim was to evaluate whether this modification resulted in a change in the delivered dose of methacholine. METHODS: Following published industry testing standards for MCT, we connected a Hamilton-G5 mechanical ventilator and Michigan lung simulator in series with respiratory rate 15 breaths/min, tidal volume (VT) 500 mL, I:E ratio 1:1 with a sinusoidal waveform. We compared methacholine dose delivery using the Hudson MicroMist and AeroEclipse II BAN nebulizers powered by either a dry gas source at 50 psi and 4.5 L/min or the Ombra compressor system, in addition to our current MCT protocol which utilizes Hudson MicroMist nebulizer with KoKo dosimeter (3 breaths). A filter placed in line between the nebulizer and test lung was weighed before and after 1 minute of nebulized methacholine delivery. Mean inhaled mass was calculated from three trials of each method with and without a viral filter on the exhalation limb. Dose delivery was calculated by multiplying the mean inhaled mass by the respirable fraction (particles < 5 µm) and inhalation time. Unpaired t-test was used to compare methacholine dose delivery with and without viral filter placement. Due to multiple independent comparisons, Bonferroni correction was used and alpha level was set at 0.01. RESULTS: The addition of a viral filter did not significantly affect methacholine dose delivery across all devices tested. Using the 50 psi dry gas source, dose delivered with the Hudson MicroMist did not differ with (461.0 µg) or without (307.8 µg) a viral filter (P=0.11) or with the AeroEclipse II BAN with (580.8 µg) or without (678.4) a viral filter (P=0.59). Using the Ombra compressor, dose delivered with the Hudson MicroMist did not differ with (1063.3 µg) or without (947.5 µg) a viral filter (P=0.026) or with AeroEclipse II BAN with (843.8 µg) or without (648.3) viral filter (P=0.42). Dose delivery did not differ significantly when using the KoKo dosimeter and Hudson MicroMist with or without a viral filter (P=0.20) using a 3-breath protocol. CONCLUSIONS: The addition of a viral filter to the nebulizer expiratory limb did not result in a significant change in the in the delivered dose of methacholine. CLINICAL IMPLICATIONS: Based on these findings, use of a viral filter to limit the concentration of expelled aerosol during MCT should be considered to improve pulmonary function technician safety and potentially reduce the risk of infectious exposure during the ongoing COVID-19 pandemic. DISCLOSURES: No relevant relationships by Kaiser Lim, source=Web Response no disclosure submitted for todd meyer;No relevant relationships by Alexander Niven, source=Web Response No relevant relationships by Paul Scanlon, source=Web Response No relevant relationships by Yosuf Subat, source=Web Response No relevant relationships by Keith Torgerud, source=Web Response
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []