Effect of the increase in valve area after aortic valve replacement with a 19-mm aortic valve prosthesis on left ventricular mass regression in patients with pure aortic stenosis.

2006 
OBJECTIVES: Although patients with aortic stenosis, who receive 19-mm valves, are at high risk for prosthesis-patient mismatch, most of them show a significant left ventricular mass (LVM) regression postoperatively. The aim of this study was to identify factors predicting postoperative relative LVM regression in this subgroup of patients. METHODS: A population of 44 patients operated on for pure aortic stenosis and receiving a 19-mm valve was studied by echocardiography at 1.4 +/- 0.5 years postoperatively. RESULTS: The mean relative LVM regression was -19.3 +/- 18.9%, the mean gradient drop was -31.6 +/- 13.3 mmHg, and the mean Delta increase in aortic area index (postoperative aortic area index minus preoperative aortic area index) was 0.30 +/- 0.14 cm/m. Thirty-two patients had an indexed effective orifice area of less than 0.8 cm/m. At multivariate analysis (r = 0.63; r = 40%; P < 0.0001) preoperative LVM (P = 0.006), hypertension (P = 0.018) and Delta aortic area index (P = 0.049) were independent predictors of relative LVM regression. CONCLUSIONS: Our study shows that, at least 1 year postoperatively, in patients receiving a 19-mm valve, LVM regression is influenced by several parameters, in particular preoperative LVM, hypertension and the magnitude of the increase in aortic area.