Effective Catheter Manoeuvre for the Removal of Phlegm by Suctioning: A Biomechanical Analysis of Experts and Novices

2020 
Purpose: The aim of this study was to determine the effective biomechanical technique for suctioning phlegm. Methods: A novel tracheal suctioning simulator combined with a motion capture system was used to calculate the amount of simulated phlegm suctioned and the biomechanical parameters of the associated suctioning manoeuvre. A laboratory study, including 12 nurses with > 3 years of suctioning experience and 12 nursing students without any clinical suctioning experience, was conducted. The amount of phlegm suctioned, the maximum length of catheter insertion, and the biomechanical parameters of hand movement were calculated. Results: The mean amount of phlegm suctioned per second was significantly larger in the experienced group than in the non-experienced group. The amount of phlegm suctioned correlated positively with the length of the vertical path of motion of the wrist and forearm, and with the angular velocity of thumb rotation in both the groups. Conclusion: Greater vertical motion of the wrist and thumb rotation improved the effectiveness of phlegm suctioning and prevented the need for deep suctioning, which is unsafe.