Fixation of distal radius fracture with volar locking palmar plates while preserving pronator quadratus through the minimally invasive approach.

2020 
BACKGROUND The volar locking plate technique with an L-shaped incision of the PQ muscle through the classic volar Henry approach is a popular method for treating distal radius fractures. Recently we revised and improved this traditional technique by performing mini-invasive surgery. OBJECTIVE The purpose of this study was to evaluate the clinical effects after fixation of distal radius fracture with volar locking palmar plates while preserving the pronator quadratus through minimally invasive approach. METHODS From May 2014 to March 2017, 58 patients (38 males and 21 females) with an age range of 22-72 years (mean age 44.6 years) and with distal radius fractures underwent open reduction and internal fixation with volar locking palmar plates. The patients were classified as 23A-2 through 23C-2 according to the Orthopedic Trauma Association fracture classification system. All surgeries were completed by one trained team. The group that received volar locking palmar plates of distal radius performed with the traditional method through Henry approach involved 33 patients (21 males and 12 females) and the group that received PQ through minimally invasive approach group involved 25 patients (16 males and 9 females). We compared the two groups for wrist pain, forearm range of motion, grip strength, preoperative complications and wrist functional recovery score. RESULTS The minimum follow-up for the whole cohort was one year. The differences between the two groups were significant in terms of wrist pain, forearm range of motion, grip strength and wrist function at 1, 2, 6 weeks postoperatively, but insignificant at 3 and 12 months postoperatively. In the minimally invasive group a case of limited extension of the forefinger 3 months postoperatively was found. No significant differences were found for preoperative complications and radiographs postoperatively. CONCLUSION Fixation with volar locking palmar plates through minimally invasive approach is a satisfactory and optional method in the treatment of distal radius fractures. This technique yields better early wrist function, shortens rehabilitation time and gets high psychological satisfaction.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    0
    Citations
    NaN
    KQI
    []