Determination of Known Exhalation Valve Damage Using a Negative Pressure User Seal Check Method on Full Facepiece Respirators

2003 
A negative pressure user seal check (NPUSC) method was evaluated for its ability to adequately detect known exhalation valve leakage into a respirator. Three valves with different types of damage were included. Twenty-six test subjects, wearing full facepiece respirators, were asked to perform a NPUSC. Their responses as to whether they passed or failed the user seal check were compared to fit testing results from two quantitative fit test methods: ambient aerosol and controlled negative pressure. In addition, equipment developed at the University of Cincinnati was used to measure in-mask pressures that are generated during the performance of NPUSCs. This technique was employed to assess the ability of respirator wearers to properly conduct user seal checks. The data were analyzed to determine if the user seal check procedure is an effective method for detecting known exhalation valve damage. All test subjects reported passing the user seal check with the undamaged valve. With the warped valve installed, ...