Objective Assessment of Nerve Injury after Greater Saphenous Vein Stripping

2007 
Aim The complication of nerve injury after greater saphenous vein stripping for varicosity is subjective, and a method for objective evaluation has never been established. The aim of this study was to evaluate postoperative sensory changes by quantitative assessment of current perception threshold (CPT), and to clarify the relation between CPT and symptoms. Patients and methods Between January 2003 and August 2005, 27 limbs in 18 patients were enrolled. Quantitative sensory function was determined through CPT using a Neurometer ® (Neurotron, Inc., USA), with which saphenous nerve neural fiber selective minimum sensing values against three electrical stimuli (2000, 250, 5Hz) were measured. CPT measurements were scheduled on the day before the operation, and 2–7 days, 1, 3, and 6 months after the operation. Results An increase in CPT value of more than 20% or decrease to below 50% compared to the preoperative value with at least two stimuli was defined as CPT abnormality. Subjective symptoms were observed in 13 limbs in the early postoperative period, and 10 limbs showed CPT abnormality. In 6 limbs with a CPT increase over 20% with all three stimuli, neurological symptoms continued for 6 months. Conclusions CPT evaluation provides an objective indication of neurological symptoms in the lower limb following varicose vein surgery.