Fracture of ankle: MRI using opposed-phase imaging obtained from turbo spin-echo modified Dixon image shows improved sensitivity

2018 
Objective:To evaluate if opposed-phase (OP) imaging obtained from the turbo spin echo (TSE) modified Dixon (mDixon) technique can increase the sensitivity of MRI for diagnosing ankle fractures.Methods:This study included 95 CT-confirmed ankle fractures with additional MRI of the ankle using a TSE modified Dixon (mDixon) technique. Two groups of images were analyzed independently: Group 1—imaging group without OP imaging; Group 2—imaging group with OP imaging. Readers assessed the images using a 4-point confidence score to detect fractures. During the first review session, the fracture site was blinded. For the second review session, the fracture site was provided. Sensitivity and positive-predictive value were calculated.Results:In both sessions, the sensitivity for Group 2 was significantly greater than that for Group 1 (Session 1: 76.3% vs 62.6%, p < 0.0001; Session 2: 80.5% vs 65.3%, p < 0.0001). The positive-predictive value of Group 2 was significantly lower in both sessions 1 and 2 (Session 1: 85.8%...