Intraobserver reproducibility and interobserver agreement of demarcation line depth measurements following corneal cross linking

2019 
Purpose:The aim of this study was to evaluate the intraobserver reproducibility of demarcation line depth measurement in keratoconic patients after epithelium-off corneal collagen cross linking and assess the interobserver variability/agreement among examiners of various experience levels.Methods:56 eyes of 56 patients undergoing corneal collagen cross linking for progressive keratoconus were enrolled. After 4 weeks, all patients underwent an anterior segment optical coherence tomography (AS-OCT; CASIA SS-1000; Tomey, Nagoya, Japan) in the cross-linked eye by four masked examiners (two medical students (S1 and S2) and two corneal fellows (F1 and F2)) in order to identify and measure the demarcation line depth in experienced and non-experienced users. The intraclass correlation coefficient and the coefficient of variation were calculated. Agreement between raters was evaluated using Bland–Altman plots, intraclass correlation coefficient and weighted-kappa statistics comparing raters in pairs.Results:The av...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    27
    References
    0
    Citations
    NaN
    KQI
    []