Hemodynamic effects of the Abdominal Aortic and Junctional Tourniquet in a hemorrhagic swine model

2017 
Abstract Background Torso hemorrhage constitutes a leading cause of battlefield mortality. The Abdominal Aortic and Junctional Tourniquet (AAJT) uses a pneumatic bladder to compress the aorta reducing pelvic and lower extremity perfusion; however, concern exists over the risk of caval compression exacerbating hypotension after application. Methods Male swine (70-90 kg) were randomized into four groups of 10: presence or absence of hemorrhage and AAJT placement. After a 40% hemorrhage, a 15-min period of hypovolemia was observed before the AAJT application. All animals received two 500 mL boluses of Hextend separated by 30 min. Cardiovascular, pulmonary, and oxygenation values were compared among groups. Results The AAJT was effective in reducing blood flow to the femoral arteries in both hemorrhaged and nonhemorrhaged animals ( P versus 61.6 ± 7.8 mm Hg, respectively, P Conclusions AAJT application in an animal model of severe shock results in a favorable hemodynamic profile because of afterload support. The present study did not demonstrate any adverse consequences because of caval compression, bowel injury, or pulmonary dysfunction. In addition, there does not appear to be any particular intravenous fluid economy achieved by AAJT application.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    25
    References
    19
    Citations
    NaN
    KQI
    []