Novel single-loop and double-loop knot stitch in comparison with the modified Mason–Allen stitch for rotator cuff repair

2015 
Purpose In rotator cuff repair, strong and long-lasting suturing techniques that do not require additional implants are needed. This study examines the ultimate load to failure and the Young’s modulus at the suture–tendon interface for a novel single-loop knot stitch and double-loop knot stitch. These values are compared to those of the modified Mason–Allen stitch.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    37
    References
    5
    Citations
    NaN
    KQI
    []