Internal dosimetry studies of 170Tm-EDTMP complex, as a bone pain palliation agent, in human tissues based on animal data.

2020 
Abstract Radiopharmaceuticals with therapeutic applications are designed to deliver high doses of radiation to target organs with minimizing unwanted radiation to healthy tissues. Owing to the potential of targeted radiotherapy to treat a wide range of malignancies, 170Tm -EDTMP was developed for possible therapeutic applications. This study describes absorbed dose prediction of 170Tm-EDTMP in human organs after animal injection which is determined via medical internal radiation dose (MIRD) and MCNP-4C code methods. It was estimated that a 1-MBq administration of 170Tm-EDTMP into the human body would result in an absorbed dose of 37.9 mGy (MIRD method) and 38.02 mGy (MCNP-4C code) in the bone surface after 60 days post injection. Highest and lowest difference between MIRD and MCNP results are for lung and bone surface respectively. Finally, the results show that there is a good agreement between MIRD method and MCNP-4C simulation code for absorbed dose estimation.