Stents liberadores de sirolimus com e sem cobertura polimérica: análise seriada com angiografia e ultrassom intracoronariano tridimensional

2009 
Sirolimus-Eluting Stents with and without Polymeric Coating: Serial Angiography and Three-dimensional Intravascular Ultrasound Analysis Background: The long-term presence of the stent polymer in contact with the vessel wall has been associated to intense inflammatory response and late adverse events. However, absence of the stent polymer may compromise drug dose and drug delivery kinetics, leading to some efficacy issues. We aimed to compare, by means of serial quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), the efficacy of the novel nonpolymeric low-dose (55 µg) VESTAsync™ (VES) sirolimus-eluting stent, with the permanent polymer, high-dose (140 µg) Cypher™ sirolimus-eluting stent (CYP). Methods: Fifteen patients with single, de novo lesions < 14 mm, in native vessels of 2.5 mm to 3.5 mm diameter, were treated with VES and compared to a paired historical cohort of 15 patients treated with CYP. QCA and IVUS data were obtained post-procedure and at 4 and 12-month follow-up. Primary endpoints were the comparison of in-stent late luminal loss and percentage of intimal hyperplasia obstruction. Results: Clinical characteristics were similar between groups. The VES group had smaller vessels (2.67 ± 0.32 mm vs. 2.98 ± 0.4 mm; P = 0.02). At 4 months, the VES group had a tendency towards a higher in-stent late luminal loss (0.30 ± 0.25 mm vs. 0.10 ± 0.3 mm; P = 0.06) but similar IVUS % of intimal hyperplasia obstruction (2.8 ± 2.2% vs. 2.2 ± 3.8%; P = 0.60). At 12-months, in-stent late luminal loss was 0.37 ± 0.24 mm (VES) vs. 0.16 ± 0.36 mm (CYP), P = 0.074, and the IVUS % of intimal hyperplasia obstruction was 4.0 ± 2.2% (VES) vs. 2.4 ± 3.9% (CYP), P = 0.17. There were no cases of binary restenosis. Conclusion: The VES proved safe and effective in reducing intimal hyperplasia formation up to 12 RESUMO Introducao: A presenca de polimeros sinteticos em contato com a parede vascular tem sido associada a intensa resposta inflamatoria local e a eventos adversos tardios. Entretanto, sua ausencia pode comprometer a eficacia dos stents farmacologicos em suprimir a hiperplasia intimal. Avaliamos, com angiografia coronariana quantitativa (ACQ) e ultrassom intracoronariano (USIC), a eficacia do stent Vestasync™ (VES), liberador nao-polimerico de sirolimus em baixa dose (55 µg), e do stent CypherTM (CYP), liberador de sirolimus polimerico em alta dose (140 µg). Metodo: Quinze pacientes com lesoes primarias < 14 mm, em arterias coronarias nativas de 2,5 mm a 3,5 mm, foram tratados com VES e comparados a uma coorte historica de
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    4
    Citations
    NaN
    KQI
    []