Two years of experience with a new device system: a multicenter study.

1995 
: Peritonitis is a crucial complication of peritoneal dialysis. Over the last few years, new device systems have been developed to reduce episodes of peritonitis caused by exogenous contamination. Remarkable improvement has been obtained by modifying the original connection between the catheter and the bag with the introduction of the Y-set. The aims of this study were to test the reliability and simple use of a double-bag system without disinfectant in-line (Gemini, Gambro) and to evaluate the incidence of peritonitis in a 2-year period of follow-up. In a group of 167 patients, enrolled in 14 dialysis units in Italy, with a follow-up of 2433 patient-months, we observed 82 episodes of peritonitis in 52 patients, with a cumulative incidence of 1 episode every 29.7 patient-months. At 12 months the percentage of patients peritonitis-free was 69.7%, and at 24 months it was 62.8%. The training to complete the bag exchange, assessed by patient and nursing staff, was defined as "easy" in 61% of the cases and "difficult" in only 12% of the cases. The percentage of patients requiring a partner was 23%. For patients this device system presents easy handling in terms of the bag exchange, and it may prevent peritonitis.