[Utility of the perfusion-assist for beating heart coronary artery bypass surgery].

2003 
During off-pump coronary artery bypass surgery, concern remains about the possible myocardial injury associated with the transient occlusion and stabilization of the target vessels. To try to minimize myocardial ischemia and achieve hemodynamic stability, we utilized a coronary perfusion catheter combined with the perfusion-assisted direct coronary artery bypass system that enables active and modified coronary perfusion of the target vessel throughout the duration of multiple grafting (modified PADCAB). In the series of 10 patients, perfusion of the target coronary systems averaged 2,072.8 +/- 649.7 ml over 92.9 +/- 26.1 minutes under a constant infusion pressure of 120 mmHg. Nitroglycerin (100 micrograms/l of flow) was delivered directly into the coronary arteries as an additive in all patients. Hemodynamic instability was notably absent in all cases, even in cases that required difficult anastomosis with a relatively long time for the anastomosis. There were no perioperative complications and no detectable myocardial damage (i.e., impairment of myocardial wall motion indicated by echocardiography findings or by > 0.25 ng/ml of troponin-T release compared to the preoperative level) in this series of patients.