Circulatory Collapse due to Hyperinflation in a Patient with Tracheobronchomalacia: A Case Report and Brief Review

2019 
We present a case of repeated cardiac arrests derived from dynamic hyperinflation in a patient with severe tracheobronchomalacia. Mechanical ventilation led to auto-PEEP with hemodynamic impairment and pulseless electric activity. Adjusted ventilation settings, deep sedation, and muscle paralysis followed by acute stenting of the affected collapsing airways restored ventilation and prevented recurrent circulatory collapse. We briefly review the pathophysiology and treatment options in patients with dynamic hyperinflation.