A randomized comparison of a novel nitinol-frame low-dose-copper intrauterine contraceptive and a copper T380S intrauterine contraceptive

2017 
Abstract Objective We sought to compare VeraCept (VC175), a novel nitinol intrauterine contraceptive (IUC) with 175 square-mm of copper surface area, to a copper T380S IUC. Study design We enrolled parous women into a randomized subject-blinded comparison of VC175 and a copper T380S in a 2:1 fashion at a single clinic. The primary outcomes were total adverse events and continuation at 12 months. We also examined pain on insertion, ease of placement, expulsion, tolerability and pregnancy. Subjective ratings were on a 5-point Likert scale (0, no pain to 5, worst pain). We followed subjects through 24-month follow-up. Results We enrolled 300 women with 199 randomized to VC175 and 101 to the T380S. Insertion was successful in 198 subjects for VC175 and 100 for the T380S. Mean age was 25 years (range 18, 41), and median parity was 2 (range 1, 8), with 39% having only had Cesarean deliveries. No subjects developed clinical infection or reported serious adverse events. In the VC175 and T380S groups, mean pain at insertion was 1.4 and 2.4, respectively (p Conclusions VC175 resulted in less pain at insertion, fewer expulsions and higher total continuation than the T380S, with similar contraceptive efficacy. Implications VC175 is a promising new intrauterine copper contraceptive on a nitinol frame that warrants further clinical trials.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    5
    Citations
    NaN
    KQI
    []